home *** CD-ROM | disk | FTP | other *** search
/ Winzipper / Winzipper_ISO.iso / nt4.0 server / DRVLIB.NIC / IBMFE / IBMFE100.DL_ / IBMFE100.DL / string.txt next >
Text File  |  1996-07-31  |  6KB  |  49 lines

  1. 1    SYSTEM\CurrentControlSet\Services\IBMFESet\IBMFE100\Parameters
  2. 2    SYSTEM\CurrentControlSet\Services
  3. 40004        Problem:     The adapter's flash chip failed diagnostics.\n           There may be a configuration conflict.\n\n    Solution:     Use your PC's EISA configuration utility to select a \n          different flash chip address.\n\n           Click Help for details.
  4. 40005        Problem:     The cable isn't attached, is damaged, or is the wrong\n           type.\n\n    Solution:     Make sure the cable is attached to the adapter.\n           Try a different cable.\n           Try a different interrupt.\n           Click Help for details.
  5. 40006        All adapter components are functioning normally.\n\n     Sent and received 1000 packets.
  6. 40007        Diagnostics were cancelled at your request.
  7. 40008        Problem:     Adapter failed network diagnostics. The problem may\n           be with the cable, network, or computer.\n\n    Solution:     Make sure the cable is attached.\n           Test the adapter in another PC.\n\n           Click Help for details.
  8. 40009        Your adapter and its driver appear to be functioning normally.
  9. 40010        Problem:     The driver didn't send any packets. This may be caused\n           by not having protocols bound to the driver.\n\n    Solution:     Verify protocol bindings from the Network Settings dialog\n           box.\n\n           Click Help for details.
  10. 40011        Problem:     The driver experienced a high number of transmit failures.\n\n    Solution:     Make sure the cable is securely attached to the adapter\n           and run this test again.\n\n           Click Help for details.
  11. 40012        Problem:     The driver didn't receive any packets at all.\n           This may be caused by a bad or missing cable.\n\n    Solution:     Make sure the cable is securely attached and run\n           this test again.\n\n           Click Help for details.
  12. 40013        Problem:     The driver experienced excessive receive failures.\n           This may be due to a bad or out of spec cable,\n           or a hub/repeater problem.\n\n    Solution:     Check your cabling and your hub.\n\n           Click Help for details.
  13. 40014        Problem:     The driver experienced excessive collisions.\n           This may be due to a very busy network, a bad cable,or a\n           hub/repeater problem.\n\n    Solution:     Check your cabling and your hub.\n\n           Click Help for details.
  14. 40015    There is no driver installed for this adapter. You may configure the driver settings once the driver is installed.\n\nUse the Network Control Panel application to install the driver for this adapter.
  15. 40016    HARDWARE\DESCRIPTION\System\CentralProcessor\0
  16. 40017        Problem:     There may be an interrupt conflict between this\n           adapter and another adapter. \n\n    Solution:     Use the PCI setup utility and select a different\n           interrupt, or try another slot.\n           Also check speed and duplex mode settings. 
  17. 40018        Problem:     The adapter has failed internal loopback. \n\nSolution:     Verify that the adapters is seated securely in its\n           slot and its settings do not conflict with other devices.
  18. 40019    The adapter did not send receive the packets it sent to itself.
  19. 40020    100Mbps Network diagnostics require a responder and none was found. You may set up a responder on this 100Mbs network or run this test on a 10Mbps network.
  20. 40021        Problem:     There may be a conflict between this adapter \n           and another card in your computer.\n\n    Solution:     Use your computer's EISA configuration utility or PCI \n           setup utility and move this adapter to another I/O address.
  21. 40023                              
  22. 40024    IBM 100/10 PCI Ethernet
  23. 40025    The adapter changed has a driver active. \nYou must shutdown Windows and power off the system for the changes to take effect.
  24. 40026    Unable to Create Diagnostic Thread.
  25. 40027    Unable to connect to Diagnostics Driver.
  26. 40028    Unable to establish a link to the Network device driver
  27. 40029    1,3,Map Registers,0,2,32,0,64,1
  28. 40030    1,3,Map Registers,0,2,8,0,64,1
  29. 40031    1,12,Map Registers,0,2,64,0,64,1
  30. 40032    1,12,Map Registers,0,2,8,0,64,1
  31. 40033    The system has not allocated an interrupt for the adapter you are installing. Please free an IRQ using your system's BIOS configuration utility and then reinstall this driver.
  32. 40034    The system has not correctly configured the adapter you are installing. Please try moving the adapter to another PCI slot and reinstall the driver.
  33. 40035    The system has not enabled bus mastering on the device you are installing, the driver will attempt to enable bus mastering when it loads. Run adapter diagnostics to see if bus mastering is allowed in this slot. 
  34. 40036    Setup was unable to stop the NDIS 3.x Device Driver. You may try this test again, or use the NDIS 3.x Driver diagnostics.
  35. 40037    The system has not enabled memory mapping for the adapter you have installed. The device driver will not work correctly on this adapter. Please try another PCI slot for this adapter or update the system BIOS and run setup again.
  36. 40038    The system has not enabled IO address mapping for the device you have installed. The device driver will not work correctly on this adapter. Please try moving the adapter to another PCI slot or update the system BIOS.
  37. 40039    Please wait while setup stops the network driver. Remember you must restart Windows to access your network after diagnostics are complete.
  38. 40040    Please wait while setup starts the network driver. Remember you must restart Windows to access your network drives.
  39. 40041    Setup has successfully started the device, press OK to return to Setup.
  40. 40042    Setup has successfully stopped the device driver. Press OK to continue the diagnostics on this adapter.
  41. 40043    You must set the Speed to either 10 or 100Mbps when the duplex mode is not set to  Automatic.\nDo not leave the Speed set to Auto Negotiate.
  42. 40044    SYSTEM\CurrentControlSet\Services\IBMFESet\IBMFE100\Parameters
  43. 40045    Unable to create Event handle. 
  44. 40046    Unable to create thread.
  45. 40047                                  
  46. 40048    i82557-based PCI Ethernet
  47. 40049    Unknown PCI Ethernet Adapter
  48. 40050    IBM 100/10 PCI Ethernet
  49.